PRPHP1636VP - 3 Ton, 15.2 SEER2, Variable Speed Packaged Heat Pump, 2 Stage, 208/230/1/60

Product Specifications

SKU:
PRPHP1636VP
AHRI - Usage:
Packaged
Air Flow Direction:
Downflow / Horizontal
Blower Motor HP:
1/2 HP
Blower Motor Type:
ECM (Electronically Commutated Motor)
Blower Wheel Diameter:
10"
Blower Wheel Width:
8"
Brand:
Heating and Cooling
CBU - Compressor Bearing Unit:
Yes
Color:
Gray
Compressor Type:
Scroll
Condenser Coil Fins per Inch (FPI):
22
Condenser Motor HP:
1/2 HP
Cooling Capacity:
34,200
COP:
2.2-3.29
Country of Origin:
USA
Cycle/Hertz:
60 Hz
Drain Connection Size:
3/4"
Drive Type:
Direct
EER2:
11.5
Energy Star Rated:
No
Equipment Type:
Heat Pump
ERP ID:
442865
ETL Listed:
Yes
Evaporator Coil Fins per Inch (FPI):
15
EPS:
Equipment
Heating Capacity:
33,200
HSPF2:
6.7
Locked Rotor Amps (LRA):
83
Maximum Overcurrent Protection (MOCP):
40
Phase:
Single
Product Family:
PRPHP16
Prop 65:
Yes
Refrigerant:
R-410A
SEER2:
15.2
Sound Level (dBA):
71
Substantial Commodity:
Steel; Copper; Aluminum
Tonnage:
3
UL Listed:
Yes
UOM:
EA
Voltage:
208-230 VAC
Weight:
446

Product Documentation

PRPHP16 TWO STAGE COMPRESSOR, VARIABLE SPEED BLOWER PACKAGED HEAT PUMP

APPLICATIONS
Designed for outdoor installations at ground level or rooftop for residential and light commercial applications.

APPROVALS
  • AHRI Certified to AHRI Standard 210/240-2008.
  • Units are design certified by ETL Intertek.
  • Heating ratings are according to Department of Energy (DOE) test procedures and Federal Trade Commission (FTC) labeling regulations and are Certified by AHRI.
  • Cooling system rated according to DOE test procedures.
  • Units are ETL certified for the U.S. and Canada.
  • Packaged unit and components within bonded for grounding to meet safety standards required by UL.
  • Each unit test operated at the factory before shipment ensuring dependable operation at start-up.
  • Seismic Certification (with Seismic Strapping Kit applied): Latest Edition of International Building Code, California Building Code, and ASCE 7-16.

REFRIGERATION SYSTEM
R-410A Refrigerant
Non-chlorine, ozone friendly, R-410A.
Unit pre-charged with refrigerant.
See Specification table.

Insulated Antimicrobial Evaporator Coil Drain Pan
Antimicrobial additive resists growth of mold and mildew on drain pan which improves indoor air quality and reduces drain line blockage.
Insulated to reduce condensation.
Includes drain pan overflow switch. Monitors condensate level in drain pan, shuts down unit if drain becomes clogged.

Outdoor Coil Fan
Weather protected heavy duty condenser fan motor with coated steel swept wing fan blades for long life.
Internally mounted.
Totally enclosed motor.
Fan guard constructed of corrosion-resistant coated steel.

Reversing Valve
4-way interchange reversing valve effects a rapid change in direction of refrigerant flow resulting in quick changeover from cooling to heating and vice versa.

High Pressure Switch
Shuts off unit if abnormal operating conditions cause the discharge pressure to rise above setting.

Loss of Charge Switch
Provides loss of charge protection by shutting off unit if liquid pressure falls below setting.


SCROLL COMPRESSOR
Two-Stage Compressor
Compressor features high efficiency with uniform suction flow, constant discharge flow, high volumetric efficiency and quiet operation.
Compressor consists of two involute spiral scrolls matched together to generate a series of crescent shaped gas pockets between them.
During compression, one scroll remains stationary while the other scroll orbits around it.
Gas is drawn into the outer pocket, the pocket is sealed as the scroll rotates.
As the spiral movement continues, gas pockets are pushed to the center of the scrolls. Volume between the pockets is simultaneously reduced.

SUPPLY AIR BLOWER
Variable Speed Direct Drive Blower
Each blower wheel statically and dynamically balanced.
Multi-speed operation is achieved by the use of an ECM (Electronically Commutated Motor) variable speed motor.
See Blower Performance tables.
Blower assembly easily removed for servicing.

ECM Variable Speed Blower Motor
Variable speed motor maintains specified air volume from 0 though 0.80 in. w.g. static range.
Motor is controlled by the blower control.
Change in blower speed is easily accomplished by simple jumper pin change on blower control.
Motor is resiliently mounted.

CABINET
Conditioned areas insulated with foil faced insulation to minimize heat loss and reduce operating sound levels.
Pre-Painted galvanized steel for maximum durability.
Full perimeter heavy-gauge galvanized steel base rails.
Base rails have rigging holes.
Two sides of the base rails have forklift slots.
Raised edges around duct and power entry openings in the bottom of the unit for water protection.
Easy service access.
Steel louvered panels provides complete coil protection.

Airflow Choice
Units are shipped with horizontal and downflow duct covers provided with unit for installation flexibility.

Electrical Inlets and Service Valves
Field wiring inlets are located in one central area of the cabinet. See dimension drawing.
Gauge ports located inside compressor service compartment of the cabinet.

WARRANTY
10 year limited parts and compressor warranty available. See limited warranty document for details.
View full details